| Name | Dale Femoral Popliteal Clamp |
| Lead Time | Lead time advised within 48 hours of order placement. |
| Specialty | Cardiothoracic-Cardiovascular Clamps |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | JBS Industries |
| Sterility | Non-Sterile |
| Usage | Reusable |
Popliteal Clamp
Popliteal Clamp
Dale Femoral Popliteal Clamp is created for use in clamping of the femoral artery which later transitions to become the popliteal artery as it travels down the leg making this vascular clamp useful in cardiothoracic surgical procedures. This clamp features a hook shaped curved jaw creating a design that allows optimal clamping of the vessel while keeping the handle and remainder of the tool out of the surgical field. This instrument is available in three sizes: small, medium and large to accommodate a variety of patients and vessel sizes.
SKU:
JBS-9763
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Popliteal Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Coarctation Clamp – 6 3/4″
SKU:
JBS-5673
Cooley Coarctation Clamp - 6 3/4"
jaws calibrated at 5.0 mm intervals, 6-3/4" (17.1 cm
Cooley Coarctation Clamp is made for use in cardiothoracic surgical procedures. The ring handles make this instrument easy to handle and manipulate and the length of the tool allows the handle out of the surgical field. Additionally, the jaws are calibrate at 5.0 mm intervals and this instrument is available with straight shanks and straight, curved or spoon jaws, or angled shanks with straight jaws making it possible to find a suitable instrument for the particular surgical procedure.
Cooley Patent Ductus Clamp – 6 1/4″
SKU:
JBS-2994
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Cooley Iliac Clamp
SKU:
JBS-3436
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Pediatric Clamp
SKU:
JBS-5236
Cooley Pediatric Clamp
delicate clamp, jaws calibrated at 5.0 mm intervals, 5-1/2" (14.0 cm)
Cooley Pediatric Clamp is ideally suited for clamping in cardiothoracic surgical procedures with pediatric patients. This clamp features jaws that are calibrated at 5.0 mm intervals but are still delicate enough for use in pediatric surgeries. This instrument is designed to keep a firm hold on the vessels that are being occluded but delicate enough not to bruise or tear the vessels thus reducing the amount of damage done to the patient. This clamp is available in a number of different styles that include straight or angled shanks and straight, satinsky, angled, or spoon-shaped jaws making this instrument highly versatile and useful in the operating room.
Cooley Anastomosis Clamp
SKU:
JBS-2412
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Aortic Aneurysm Clamp
SKU:
JBS-3139
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Anastomosis Clamp Modified
SKU:
JBS-3714
Anastomosis Clamp Modified
30 degree side angled jaws, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp Modified is ideally used in cardiothoracic surgeries that require anastomosis between vessels and thus a clamp is utilized to reduce but not completely occlude blood flow. This instrument is hand-crafted by certified instrument makers to conform to the highest standards in instrumentation. Additionally, this modified anastomosis clamp features a 30 degree side angled jaw making it more able to access harder to reach vessels.
Exclusion Clamp
SKU:
JBS-6623
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.

Reviews
There are no reviews yet.