| Name | Cooley Acutely Curved Clamp |
| Lead Time | Lead time advised within 48 hours of order placement. |
| Specialty | Cardiothoracic-Cardiovascular Clamps |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | JBS Industries |
| Sterility | Non-Sterile |
| Usage | Reusable |
Cooley Acutely Curved Clamp
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2″ (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
SKU:
JBS-2341
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Acutely Curved Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Neonatal Clamp
SKU:
JBS-7928
Cooley Neonatal Clamp
5" (12.5 cm)
Cooley Neonatal Clamp is the ideal tool for use in surgical procedures for newborn children. This clamp is build sturdily but made small enough to clamp the delicate vessels of a newborn child. This instrument is particularly well suited due to its ability to maintain a hold on the vessel without causing tears or rip on the delicate vessel walls of the newborn. Additionally, this clamp is available in a straight profile, spoon jawed, anastomosis clamp, carotid clamp or angled shank and straight jaws or curved shanks and angled jaws.
Beck Vascular Clamp
SKU:
JBS-5368
Beck Vascular Clamp
cooley jaws calibrated at 5.0 mm intervals, straight shanks, 6" (15.0 cm)
Beck Vascular Clamp is suited for optimal use in cardiothoracic surgical procedures. This clamp is designed to clamp vessels and occlude blood flow during surgical procedures in many cases to prevent an excessive amount of blood loss from the patient. A unique feature of this clamp is the curved Cooley jaws that are calibrated at 50 mm intervals as well as the straight shanks. This instrument is available two sizes: small jaw with heavy curvature and large jaw with medium curvature.
Cooley Tangential Occlusion Clamp
SKU:
JBS-9863
Cooley Tangential Occlusion Clamp
double angled jaws calibrated at 5.0 mm intervals, 7-3/4" (19.5 cm)
Cooley Tangential Occlusion Clamp is uniquely designed to clamp vessels in a way that reduces blood flow without completely stopping it in cardiothoracic surgical procedures. This clamp can be best used when doing procedures such as side-by-side anastomosis that required some blood flow. Additionally, this instrument features double angled jaws that are calibrated at 5 mm intervals making it possible to make accurate measurements during the procedure.
Cooley Aortic Aneurysm Clamp
SKU:
JBS-3139
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Coarctation Clamp – 9 3/4″
SKU:
JBS-6165
Cooley Coarctation Clamp - 9 3/4"
7.0 cm long straight jaws, straight shanks, 9-3/4" (24.8 cm)
Cooley Coractation Clamp is well suited for use in cardiothoracic surgical procedures that necessitate total or partial occlusion of a vessel. This is often done in cardiothoracic surgical procedures to prevent the patients from losing an excessive amount of blood during surgery. This pattern features longer jaws and a longer overall length for cases where additional reach is necessary, as well as straight jaws and shanks which are designed to provide a firm and stable grip once they have been affixed to the site where the clamping is needed.
Cooley Iliac Clamp
SKU:
JBS-3436
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Cardiovascular Clamp
SKU:
JBS-3261
Cooley Cardiovascular Clamp
2" (5.1 cm) curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is an ideal tool for use in cardiothoracic surgical procedures that require clamping of vessels to prevent excessive bleeding. This instrument is designed with two inch curved jaws that allow for stable closure of vessel while maintaining gentle enough pressure on the vessel wall to prevent damage or tearing. Additionally, this clamp features a ratcheting mechanisms to keep the clamp locked in place during surgery.
Bailey Aorta Clamp
SKU:
JBS-6873
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.